Calculation of stent-graft fenestration points for supraceliac aortic endografting: design and application of universal calibrated models
https://doi.org/10.29001/2073-8552-2026-41-2-114-123
Abstract
Background. Fenestrated abdominal aortic repair is a minimally invasive solution in the treatment of juxtarenal aneurysms and pararenal aneurysms. After fenestration, the success of renal branch catheterization depends on the correct positioning of the stent-graft relative to the artery mouth. At the same time, with more fenestrations the success of arterial catheterization depends on the exact alignment of fenestras. The article suggests methods for determining endograft fenestration points for fenestrated abdominal aortic repair of Juxtarenal aneurysms and pararenal aneurysms using universal models with a dimensional grid and a measuring ruler printed on a 3D printer. The proposed approaches, both individually and together, can increase the accuracy of selecting points for endograft fenestration, which may improve the results of Fenestrated abdominal aortic repair Juxtarenal aneurysms and pararenal aneurysms.
Aim: To assess the effectiveness of fenestration of an endovascular prosthesis using additional universal devices (universal aortic models and a measuring ruler) to select the fenestration point during endovascular prosthetics of abdominal aortic aneurysms with juxtarenal and pararenal localization.
Material and Methods. Aortic models with a dimensional grid and a measuring ruler were designed, followed by the production of models and rulers with 3D printing. The study involved 7 male patients with juxtarenal and pararenal abdominal aortic aneurysms who underwent primary elective endovascular aortic repair using fenestration on the operating table (performing 2 fenestration) using aortic models and an stent-graft measuring ruler.
Results. Technical and procedural success is achieved in 100% of cases. The target or close to the target position was achieved in all patients. There were no positional errors. No endoliths of types 1A and 3 were registered. There were no difficulties in cannulation and endograft insertion into the renal arteries.
Conclusion. The technology of endograft fenestration using additional universal tools (universal models, measuring ruler) for selecting fenestration points in juxtarenal and pararenal endovascular repair can be considered an effective, cost-efficient alternative, offering the potential to reduce waiting times for intervention in patients at high risk of aneurysm rupture.
About the Authors
R. S. PolyakovRussian Federation
Roman S. Polyakov - Dr. Sci. (Med.), Senior Research Scientist, Petrovsky National Research Center of Surgery.
2, Abrikosovskij pereulok str., Moscow, 119991
G. S. Vlasko
Russian Federation
Gordey S. Vlasko - Cand. Sci. (Med.), Junior Research Scientist, Petrovsky National Research Center of Surgery; Surgeon, Department of X-ray Surgery, National Medical Research Treatment and Rehabilitation Center.
2, Abrikosovskij pereulok str., Moscow, 119991; 3, Ivan'kovskoe shosse str., Moscow, 125367
D. A. Karamyan
Russian Federation
Dzhul'etta A. Karamyan - Cand. Sci. (Med.), Surgeon, Department of X-ray Surgery, Medical Research and Educational Center of Lomonosov; Senior Research Scientist, Department Moscow Regional Research and Clinical Institute.
27, Lomonosovskij prospect str., Moscow, 119192; 61/2, Shchepkina str., Moscow, 129110
M. V. Pureckiy
Russian Federation
Mikhail V. Pureckiy - Dr. Sci. (Med.), Senior Research Scientist, Department of X-ray Surgery, Petrovsky National Research Center of Surgery.
2, Abrikosovskij pereulok str., Moscow, 119991
H. V. Mardanyan
Russian Federation
Hayk V. Mardanyan - Dr. Sci. (Med.), Leading Research Scientist, Department of X-ray Surgery, Petrovsky National Research Center of Surgery.
2, Abrikosovskij pereulok str., Moscow, 119991
K. A. Kur-ipa
Russian Federation
Kiazim A. Kur-ipa - Graduate Student, Department of X-ray Surgery, Petrovsky National Research Center of Surgery.
2, Abrikosovskij pereulok str., Moscow, 119991
V. M. Safonova
Russian Federation
Vera M. Safonova - Graduate Student, Department of X-ray Surgery, Petrovsky National Research Center of Surgery.
2, Abrikosovskij pereulok str., Moscow, 119991
Yu. M. Saakyan
Russian Federation
Yuri M. Saakyan - Dr. Sci. (Med.), Senior Research Scientist, Department of X-ray Surgery, Petrovsky National Research Center of Surgery.
2, Abrikosovskij pereulok str., Moscow, 119991
S. A. Abugov
Russian Federation
Sergey A. Abugov - Dr. Sci. (Med.), Corresponding Member of the Russian Academy of Sciences, Head of the Department of X-ray Surgery, Petrovsky National Research Center of Surgery.
2, Abrikosovskij pereulok str., Moscow, 119991
References
1. Cherian A.M., Venu R., Raja P.I. et al. Outcomes of Endovascular Aneurysm Repair (EVAR) Compared to Open Repair in Abdominal Aortic Aneurysm: An Umbrella Meta-Analysis. Cureus. 2024;26;16(6):e63183. https://doi.org/10.7759/cureus.63183
2. Mees B. FEVAR Is Durable, Now Let's Focus On the Patient's Durability. Eur. J. Vasc. Endovasc. Surg. 2023;66(2):167–168. https://doi.org/10.1016/j.ejvs.2023.06.013
3. Baldeh T., Reilly T., Mansoor T. et al. Systematic Review and Meta-analysis of Fenestrated and Chimney/Snorkel Techniques for Endovascular Repair of Juxtarenal Aortic Aneurysms. J. Endovasc. Ther. 2025;32(6):1836–1845. https://doi.org/10.1177/15266028241231171
4. Abugov S.A., Vlasko G.S., Polyakov R.S. et al. Endovascular aneurysm repair using fenestrated endoprostheses made to order from the manufacturer: Case report. Consilium Medicum. 2023;25(10):698–702. (In Russ.). https://doi.org/10.26442/20751753.2023.10.202254
5. Polyakov R.S., Puretskiy M.V., Mardanyan G.V. et al. The use of physician-modified stent graft during EVAR in patient with juxtarenal aneurysm. Clinical and Experimental Surgery. Petrovsky Journal. 2022;10(4):16–21. (In Russ.). https://doi.org/10.33029/2308-1198-2022-10-4-16-21
6. Coles-Black J., Bolton D., Robinson D., Chuen J. Utility of 3D printed abdominal aortic aneurysm phantoms: a systematic review. ANZ J. Surg. 2021;91(9):1673–1681. https://doi.org/10.1111/ans.16763
7. Karelis A., Dias N.V. Navigating the Twist and Turn: Deciphering Misalignment in FEVAR. Eur. J. Vasc. Endovasc. Surg. 2024;67(5):775– 776. https://doi.org/10.1016/j.ejvs.2023.11.014
8. Rynio P., Gutowski P., Kazimierczak A. Physician-Modified Stent-Grafts Created in the Three-Dimensionally Aortic Template Have Better Reliability and Greater Alignment With the Target Vessels Than Stent-Grafts Modified Based on Measurements From Computed Tomography. J. Endovasc. Ther. 2023;30(5):769–778. https://doi.org/10.1177/15266028221095396
9. Verhoeven E.L., Katsargyris A., Fernandes e Fernandes R. et al. Practical points of attention beyond instructions for use with the Zenith fenestrated stent graft. J. Vasc. Surg. 2014;60(1):246–252. https://doi.org/10.1016/j.jvs.2014.01.065
10. Uflacker R., Robison J.D., Schonholz C., Ivancev K. Clinical experience with a customized fenestrated endograft for juxtarenal abdominal aortic aneurysm repair. J. Vasc. Interv. Radiol. 2006;17(12):1935–1942. https://doi.org/10.1097/01.RVI.0000248828.92093.1A
11. Nordon I.M., Hinchliffe R.J., Manning B. et al. Toward an “off-the-shelf” fenestrated endograft for management of short-necked abdominal aortic aneurysms: an analysis of current graft morphological diversity. J. Endovasc. Ther. 2010;17(1):78–85. https://doi.org/10.1583/09-2895R.1
12. Derycke L., Sénémaud J., Perrin D. et al. Patient Specific Computer Modelling for Automated Sizing of Fenestrated Stent Grafts. Eur. J. Vasc. Endovasc. Surg. 2020;59(2):237–246. https://doi.org/10.1016/j.ejvs.2019.10.009
13. Li Y., Hu Z., Bai C. et al. Fenestrated and Chimney Technique for Juxtarenal Aortic Aneurysm: A Systematic Review and Pooled Data Analysis. Sci. Rep. 2016;12(6):20497. https://doi.org/10.1038/srep20497
14. Coles-Black J., Bolton D., Chuen J. Accessing 3D Printed Vascular Phantoms for Procedural Simulation. Front. Surg. 2021;27(7):626212. https://doi.org/10.3389/fsurg.2020.626212
Review
For citations:
Polyakov R.S., Vlasko G.S., Karamyan D.A., Pureckiy M.V., Mardanyan H.V., Kur-ipa K.A., Safonova V.M., Saakyan Yu.M., Abugov S.A. Calculation of stent-graft fenestration points for supraceliac aortic endografting: design and application of universal calibrated models. Siberian Journal of Clinical and Experimental Medicine. 2026;41(2):114-123. (In Russ.) https://doi.org/10.29001/2073-8552-2026-41-2-114-123
JATS XML


.png)